Descargar Imprimir esta página

GF U1000 V2 Wallmount WM Instrucciones De Uso página 39

Ocultar thumbs Ver también para U1000 V2 Wallmount WM:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 130
User Manual
8.7
Data entry errors
Data entry errors generally advise you that the data entered is not within the specified range.
Error Message
Range 20.0 - 215.0
0.000 mm
Calibrate Error
Press Enter
Range 1 - 200
200
Range 3 - 99
0000.0
Range 0.00 - 0.500
0000.0
Range 0.500 - 1.500
0000.0
Address
Command
[1 byte]
[1 byte]
0x01
0x03
0x01
0x8C
0x01
0x83
0x01
0x83
0x01
0x83
0x01
0x83
9
Removal
Switch off the external power supply and prevent it from being switched on again.
Disconnect all cable connections.
Loosen the pipe clamps and remove the GF U1000 V2 completely from the pipe along with all connecting cables.
Displayed when an invalid Pipe ID is entered, prompting the user to enter a value between
20 and 215 mm depending on the product purchased.
An attempt has been made to zero the offset between the temperature sensors, and the
difference in temperature is too large. Ensure the temperature sensors are correctly
plugged in and are both at the same temperature.
When programming a Frequency Pulse output the frequency is limited to the range 1 to
200 Hz.
When programming a Volume Pulse output the pulse width is limited to the range 3 to
99ms.
When programming the Zero Cut-off this is limited to the range 0.000 to 0.500.
Note: This must be set to zero before performing a zero offset.
When programming the Calibration Factor this is limited to the range 0.5 to 1.5.
Receiver
Error code
CRC-16
[1 byte]
[2 bytes]
None
n/a
0x01
0x85
0x02
0xC0
0x03
0x01
0x06
0xC1
0x07
0x00
Cause and remedy
n/a
Example of a good message
The only acceptable commands are 0x03
0x00
and 0x06
0xF1
Incorrect register start
0x31
Incorrect register length
worker is busy processing and is unable
0x32
to respond
0xF2
CRC is incorrect
Removal
Comments
39

Publicidad

loading

Este manual también es adecuado para:

U1000 v2 wallmount whm