a) pedal
b) welding torch with start button
c) welding torch with potentiometer (5 kΩ)
d) welding torch with up/down etc...
G – SWITCH
Starts and stops the machine
H – GAS INPUT FITTING
4 DESCRIPTION OF DISPLAY
sions.
The display then presents the main screen (factory setting). The
operator may start welding immediately and may adjust the cur-
rent by turning knob B
S
R
Q
P
O
As seen in the fi gure, the display is divided into sectors.
In each sector, settings operations may be conducted.
• To select sectors, press and release knob B so that
a sector is highlighted in red.
Turn knob B to select the desired sector, and then
briefl y press knob B to access the settings of the se-
lected sector.
• The most recent setting is highlighted in green,
and boxed in red; with the new selection, the red box
moves to the new choice.
IMPORTANT
from now on, this procedure shall be
described indicating:
select and confi rm
on confi rmation, this symbol returns
to the screen previous to that in use
During start-
up, for 5 sec-
onds the dis-
play presents
all the infor-
mation
re-
garding
the
welding ma-
chine
soft-
ware
ver-
T
I
L
M
N
U
on selecting and confi rming this
symbol,
shall be set
IMPORTANT
To return to the main screen from
any condition, press and hold knob
B (> 0.7 sec.)
IMPORTANT
The available options depend on the
selections made previously
4.1 SECTOR I WIZARD (WIZ)
This function enables rapid setting of the welding machine.
4.1.1 SETTING THE WELDING PROCESS (PARA-
GRAPH 5)
4.1.2 SETTING ARC IGNITION (PARAGRAPH 6)
the
factory
parameters
Select
and
confi rm the
WIZ sector.
The
next
choice is au-
tomatically
displayed
Select
and
confi rm the
welding pro-
c e s s . T h e
next choice
is automat-
ically
dis-
played.
Select
and
confi rm type
of
ignition.
The
next
choice is au-
tomatically
displayed.
23