Mounting
Fig. 3
1 Wall / pipe
2 Mount
Warning - General dangers!
The transmitter can fall and be damaged if not firmly attached. There is also a risk of persons
being injured as a result.
Always ensure that the mount is secured to a sufficiently stable point.
Wall mounting:
Attach the wall mount to the wall using
4 screws (Ø 10 mm).
CI/TTF300-X1
1
2
TTF300
3
4
3 Transmitter
4 Lock screw
Pipe mounting:
Attach the pipe mount to the pipe using 2 pipe
clamps (Ø 10 mm). The pipe mount can be
attached to a pipe with a maximum diameter of
2.5".
Mounting
1
2
A00268
EN - 11