4. Design and function

4. Design and function

4.1 Description

Pressures p
EN
1
an elastic diaphragm (1).
The differential pressure (∆p = p
phragm against the measuring range springs (2).
The deflection, which is proportional to the differential pressure, is transmitted to
the movement (4) in the indicating case and to the leaf springs of the micro swit-
ches (5) via a pressure-tight and low friction rocker arm (3).
Overpressure safety is provided by metal bolsters (6) resting against the elastic
diaphragm.
The setting of the switch point is made by the adjustment screws accessible from
the front (7).
The assistant scales (8) simplify the setting of the switch points.

4.2 Scope of delivery

Cross-check scope of delivery with delivery note.
18
and p
act on the media chambers ⊕ and ⊖, which are separated by
2
WIKA operating instructions DPGS40TA with component testing
- p
) leads to an axial deflection of the dia-
1
2