Adjust the fl oor-mounted feet (A) to level the
appliance.
To make the connection, connect the mains
line to the appliance's connection pipe, fi tting a
shut-off tap (A), to allow the water supply to be
cut off when necessary.
Easily accessible fi lters must be fi tted downstream
of the tap.
Caution - Warning
The appliance must be supplied with
drinking water having the characteristics
shown in the table.
Parameters to be checked
Pressure
GB
pH
TDS
Hardness
Langelier index ( Recommended) (**)
Salt and metallic ion content
Requested
Recommended (**)
(**) Values diff erent from these parameters may cause corrosion if combined with wrong use and environment.
3320140_inst_GB_rev.1
LEVELLING
WATER CONNECTION
Chlorine
Chlorides
Sulphates
Iron
Copper
Manganese
- 10 -
A
A
Value
200÷400 kPa (2÷4 bar)
7÷8.5
40÷150 ppm
3÷9°f (1,5÷5°d, 2.1÷6.3°e, 30÷90 ppm)
>0.5
<0,1 mg/l
<10 mg/l
<30 mg/l
<0,1 mg/l
<0,05 mg/l
<0,05 mg/l
ENGLISH