The appliance has been tested before being put
into service. The information provided below is
intended to assist in the identifi cation and cor-
rection of any anomalies and malfunctions which
might occur during use.
The user can solve some of these problems him-
self, but for others specifi c technical knowledge or
skill is required, and so they must only be carried
out by qualifi ed staff with recognised experience
acquired in the specifi c sector of operation.
Faults
The heating elements do
not come on
The pressure gauge has
detected an abnormal
pressure (> 0,5 bar) inside
the jacket
The safety thermostat is
tripped too often
GB
3320140_ut_GB_rev.1
FAULT
TROUBLESHOOTING
For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Electrical connection not
made correctly
Safety thermostat tripped
Switch faulty
Pressure control valve fouled
or damaged
The water level in the jacket
is not correct
- 14 -
Important
Remedies
Check the connection of the elec-
trical wires
Carry out the appliance reset
(see page 11).
Replace the switch
Clean the pressure control valve
and call the after-sales service if
necessary
Restore the water level in the ja-
cket; if necessary call the aftersales
service
ENGLISH