Failure
Possible solution
Let a small amount of WD-40 through the air inlet. Run the tool for a few seconds. The blades may stick to the rotor. Run the tool for
The tool has too slow
about 30 seconds. Lubricate the tool with small amount of oil. Attention! The excess of oil can cause a decrease in power of tool. In this
rotations or it does not start
case, you should clean the drive.
The tool starts and then
The compressor does not provide proper air supply. The tool starts by the air collected in the tank of compressor. As the tank is
slows down
emptying, the compressor has not kept pace with the refi lling of air shortages. Connect the device to a more effi cient compressor.
Make sure that your hoses have an internal diameter of at least such as specifi ed in the table in point 3. Check the set point of pressure,
Insuffi cient power
whether it is set to the maximum value. Make sure that the tool is properly cleaned and lubricated. In the absence of results, submit the
tool for repair.
Replacement parts
In order to obtain the information on spare parts for pneumatic tools, you must contact the manufacturer or its representative.
Worn tools are secondary raw materials - it is forbidden to dispose of them together with household waste because they contain
substances harmful to human health and the environment! Please actively support the cost-eff ective management of natural re-
sources and environmental protection by passing the used equipment to the point of storage for worn out devices. To reduce the
amount of disposed waste it is necessary to re-use them, recycle or recover in another form.
O R I G I N A L
14
EN
I N S T R U C T I O N S