Spacer
E-Ring
Missing Tooth
Detent
3. Installation for 2-Way
IMPORTANT! This valve is not intended to be used as a shut-off
valve. Complete the 2-way conversion before plugging any outlets.
2-Way Conversion
Temporarily remove the plaster guard.
Rotate the detent until positioned vertically.
Verify that the missing tooth is oriented up.
IMPORTANT! If the internal plug is not removed, the finished wall
will need to be removed to perform this step at a later date.
Using a 1/4" hex wrench, remove and discard the internal plug
from inside the valve body.
Plug the unused port (left or right) with a 1/2" NPT plug (not
included).
Using pliers, remove the spacer from the detent.
Push the detent in, ensuring that the points of the detent engage
with the notches of the valve cartridge.
Install the spacer between the detent and E-ring.
Install the 2-Way Valve
Install 1/2" copper tubing or piping for both accessories. Securely
fasten the piping and outlet elbows to the framing.
1091987-2-E
Accessory #2
Accessory #1
Water Line
Water Line
1/2"
Plaster
NPT Plug
Guard
6
Internal
Plug