INSTALLATION INSTRUCTIONS
 Ensure the valve stem adapter is lightly placed over the spline adapter.
 Place the handle assembly over the valve stem adapter.
 Turn the handle clockwise until the stop is contacted. The valve will be in the full cold position. The handle
should be between 9 and 10 o'clock positions. To adjust the position of the handle, refer to the alignment
instructions below.
 Rotate the handle assembly counterclockwise, through the detent, then to the high temperature limit stop.
 Verify that the handle assembly is between the 3 and 4 o'clock position.
 Rotate back to the 6 o'clock position.
 Remove the handle assembly and set aside.
Handle Alignment Adjustments
NOTE: The spline adapter allows fi ne adjustment of the handle alignment.
 Remove the handle assembly and the valve stem adapter.
 Reposition the spline adapter.
 Reinstall the handle assembly and the valve stem adapter.
 Check the alignment.
 Repeat until the handle alignment is satisfactory.
1048650-2-K
4 of 6
2. ADJUST THE HANDLE ASSEMBLY
Spline Adapter
Valve Stem Adapter
Thermostatic Valve Trim
Handle Assembly