KNOW YOUR GENERATOR
Read this owner's manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Circuit Breakers (AC)
Hour Meter
Idle Control Switch
Ignition Switch
12 Volt DC
Receptacle
120 Volt AC, 20 Amp
Duplex Receptacles
120 Volt AC, 30 Amp
Locking Receptacle
120/240 Volt AC, 30 Amp
Locking Receptacle
12 Volt DC Receptacle — Use this receptacle with battery
charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp Duplex Receptacles — May be used to
supply electrical power for the operation of 120 Volt AC, 20 Amp,
single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May be used to
supply electrical power for the operation of 120 Volt AC, 30 Amp,
single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of 120 and/or
240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
Air Cleaner — Protects engine by filtering dust and debris out
of intake air.
Choke Lever — Used when starting a cold engine.
Circuit Breakers (AC) — Push to reset circuit breakers are
provided to protect the generator against electrical overload.
Data Tag – Provides model, revision and serial number of
generator. Please have these readily available if calling for assistance.
BSPP Generator
Oil Fill Cap
Fuel Tank
Grounding
Fastener
5
www.mymowerparts.com
Air Cleaner
Rocker Switch
Circuit Breaker
GFCI Circuit Breaker
Data Tag
Fuel Tank — Capacity of seven (7) U.S. gallons.
GFCI Circuit Breaker — A GFCI circuit breaker is provided to
protect against electrical ground fault and protect the generator
against electrical overload.
Grounding Fastener — If required, please consult a qualified
electrician, electrical inspector, or local agency having jurisdiction.
Hour Meter — Displays and records how many hours your
generator has run (up to 9,999.9).
Idle Control Switch — The idle control runs the engine at
normal (high) speeds when there is a load present and runs the
engine at idle (low) speeds when a load is not present.
Ignition Switch — Push to start and stop the engine.
Oil Fill Cap — Add oil to engine here.
Rocker Switch Circuit Breaker — The 30A locking receptacles
are provided with a rocker switch circuit breaker to protect the
generator against electrical overload.
Spark Arrester Muffler — Exhaust muffler lowers engine noise
and is equipped with a spark arrester screen.
Choke Lever