Displays the number of complete cycles (open+close) carried out by the automation.
NMAN
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the
last 4. Example <PG> 0012
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again
RES
resets the control unit.
Note: The transmitter codes are not erased from the receiver.
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s
- activate pre-blinking
Perform the operations described below step by step:
All manuals and user guides at all-guides.com
FUNCTION
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
Off: Receiver enabled for rolling-code and programmable code
transmitters (self-learning and Dip Switch).
The operation mode of the amperometric sensor is selected ei-
ther the limit switches are provided or not.
Off: Limit switches provided. The amperometric sensor activa-
tion is interpreted by the control unit as obstacle present in the
gate movement area. Similarly to the safety edge activation, the
control signal is sent to stop and reverse movement for approx.
3s.
On: Limit switches not provided. The amperometric sensor
activation is interpreted by the control unit as limit switch. The
control signal is sent to stop the movement. Note: To use this
function, close the limit switch contacts with jumpers.
The output performance at Terminals 9-10:
On: The output has the function of 2
mally open contact switches for 1s at reception of a radio control
assigned to the 2
radio channel. See radio menu.
nd
Off: The output has the SCA function, open gate LED: open
contact with closed gate, flashing light during gate movement,
closed contact with open gate. See wire diagram.
Service light function is enabled or disabled on output 9-10.
On: at each movement, the contact is closed for approx. 90s,
regardless of the configuration of 2ch parameter.
For the light control use the auxiliary relay.
Off: The performance of the output is preset by 2ch parameter,
see previous parameter.
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the step-
by-step function.
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be assigned to the second
radio channel, on Terminals 9-10.
The 2ch logic must be ON, the SERL logic must be OFF.
Press the transmitter key to be assigned to this function.
If the code is valid, it is stored in memory and OK appears.
If the code is not valid, the wording Err is displayed.
By selecting this function, the receiver awaits (Push) for a transmitter code to be erased from memory.
If the code is valid, it is erase and OK appears.
If the code is not valid or is not in memory, the wording Err is displayed.
Completely erase the receiver memory. Confirmation of operation is required.
>>> <PG> 3456: made 123.456 cycles.
Example of programming
radio channel: the nor-
nd
FUNCTION
FUNCTION
Settable values
MEMO
ON-OFF-(Default)
OFF
(OFF)
(OFF)
(OFF)
13