1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want (PAR>>LOG>>RADIO>>NMAN>>RES>>PAR>>....).
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 60s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Operating time, motor 1. The operating time is adjusted at normal speed
TM1
during motor 1 opening and closing phases. See section "Adjustment of
braking".
Operating time, motor 2. The operating time is adjusted at normal speed
TM2
during motor 2 opening and closing phases. See section "Adjustment of
braking".
PMo1
The torque applied to motor 1 during the opening phase is adjusted. *
PMC1
The torque applied to motor 1 during the closing phase is adjusted.*
PMo2
The torque applied to motor 2 during the opening phase is adjusted.*
PMc2
The torque applied to motor 2 during the closing phase is adjusted.*
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Electric lock activation time. If the electric lock is not used, set the param-
TLOc
eter at 0.
The motor speed during braking is adjusted. The value is expressed in per-
SLDS
centage with respect to speed during normal operation.
The torque applied to motor 1 during braking in the closing phase is ad-
Pso1
justed *
The torque applied to motor 1 during braking in the opening phase is ad-
Psc1
justed *
The torque applied to motor 2 during braking in the closing phase is ad-
Pso2
justed *
The torque applied to motor 2 during braking in the opening phase is ad-
Psc2
justed *
* WARNING: An incorrect setting of these parameters may result in an hazard. Comply with regulations in force!
Adjustment of braking
With braking enabled (SLD logic: ON), braking will start at end of time preset with TM1 and TM2.
The preset time should therefore be lower than the real stroke of the operator. For example, with a 20s stroke, preset 17s to start
the braking phase, 3s in advance with respect to end of movement.
Note: The TM1 and TM2 parameters do not work with braking disabled (SLD logic: OFF), as the end of operation is determined
only by the triggering of the limit switch or by the amperometric sensor. The speed of the motor during braking is determined by
the SLDS parameter value.
All manuals and user guides at all-guides.com
To access programming:
Notes:
Parameters, Logic and Special Functions
FUNCTION
Settable values
MEMO
MIN-MAX-(Default)
1-240-(40s)
5-180-(9s)
5-180-(9s)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)
0-15-(2s)
0-40-(3s)
0-5-(3s)
30-99-(30)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)
11