TECHNICAL CHARACTERISTICS
14
PHYSICAL
Connection: by 0.5 to 6 mm
terminals.
Weight: 300 g
90
COUNTIS AT
FRONT PANEL
Display:
• 7 digits electromechanical
0 to 9 999 999 kWh
• accuracy: ± 1 Digit
5-mm diameter red (energy or CT
connection)
and green LEDs (ON/OFF)
Protection index: IP 54.
NETWORK
Balanced or unbalanced 3 or 4 wire.
CURRENT INPUTS
From transformer with:
• micro-switches configurable primary:
10 - 20 ... - 4000 A
• secondary: 5 A (1 A on request)
Consumption: ≤ 0,4 VA
Measurement range: 1 A to 4800 A
Overload:
• permanent: 7 A
• intermittent: 10 A for 1 second
VOLTAGE INPUTS
Measurement range:
• between phases: 90 to 500 V AC
• between phase and neutral:
51 to 289 V AC
Permanent overload: 289 V AC
(phase/neutral)
2
fixed
106
93
58
48
26,5
45 62
SOCOMEC - Réf. : 875 503D