TECHNICAL CHARACTERISTICS
SOCOMEC - Réf. : 875 503D
ACCURACY
Active energy: IEC 1036, class 1 for the
ATi and class 2 for the AT
AUXILIARY POWER SUPPLY
230 V or 400 V AC, 50/60 Hz
Tolerance: ± 15 %
Consumption: 4 VA
PULSE OUTPUT
1 T reed relay (100 V DC - 0.5 A - 10 VA)
Pulse time: 100 ms
Number of manipulations:
100 x 10
6
minimum
Micro-switch programmable pulse value:
100 Wh / 1 kWh / 10 kWh / 100 kWh
2
nd
pulse output (optional):
• connected in parallel to the first
• independent from the first
GALVANIC INSULATION
Auxiliary power supply: 2.5 kV AC
for 1 minute
Current inputs: 2.5 kV AC
for 1 minute
Pulse output: 2.5 kV AC
for 1 minute
OPERATING CONDITIONS
Operating temperature: -10 to +60°C
Storage temperature: -20 to +70°C
Relative humidity: 95%
STANDARDS
Active energy accuracy:
• IEC 1036, class 1 for the ATi and class
2 for the AT
CE marking:
• EN 50081-2
• EN 50082-2
• CEI 1000-4-2/3-4-5-6-8-11
Operating conditions:
• CEI 68-2-11/30