Descargar Imprimir esta página

SICK WSE26P Instrucciones De Uso página 37

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
10
Disassembly and disposal
11
Maintenance
8020358.1GI9/2022-07-13 | SICK
Subject to change without notice
LED/fault pattern
WEO:Green LED flashes
Switching outputs do not
behave in accordance with
table 5
Not all blue LEDs light up.
No object in beam path, no
output signal
Yellow LED flashes
Yellow LED lights up, although
an object is in the path of the
beam.
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
OPERATING INSTRUCTIONS
Cause
IO-Link communication
1. Change of the configuration
2. Short-circuit
a) Insufficient alignment
b) Contamination of the opti‐
cal surfaces
c) Particles in the light beam
d) Distance between sender
(WS) and receiver (WE) is
too large
Test input (Test) is not con‐
nected properly
Distance between sender
(WS) and receiver (WE) is too
large / Beam of WS is not
completely on WE or WE is not
aligned to WS
The beam of light of a pho‐
toelectric through-beam sen‐
sor hits the receiver of
another (neighboring) photo‐
electric through-beam sensor
O P E R A T I N G I N S T R U C T I O N S | WSE26
Measures
None
1. Adjustment of the configura‐
tion
2. Check electrical connections
a) Check alignment
b) Cleaning of the optical sur‐
faces.
c) Avoid contamination in the
air as far as possible
d) Check sensing range
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
Check sensing range,
see
figure 8
Check alignment
Swap the sender and receiver
arrangement at every sec‐
ond through-beam photoelec‐
tric sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
en
37

Publicidad

loading

Este manual también es adecuado para:

Wse26iWse26g