Description
25 ft. remote and in-line blower
extension cable
Available to connect the hood to the
inline and remote blowers for distances
up to 25 ft.
4.3 Hood transition
Discharge direction
The exhaust air is discharged upwards through a duct or
directly through the outside wall into the open.
The hood can be mounted on the wall only with a vertical
discharge.
Attaching the hood transition
Your hood is supplied with a 10" (254 mm) round
transition. A locally supplied transition is required for other
sizes.
A minimum height clearance of 6½" (165 mm) is
1.
needed above the hood for transition mounting.
Align the mounting holes at the base of the transition
2.
over the mounting holes of the ½" (13 mm) flange
located at the top of the hood.
Fasten the transition to the hood using four (4) ¼"
3.
(6 mm) sheet metal screws included with the hood.
Note: Make sure the screws do not hinder the damper
operation.
Seal the connection between transition and hood with
SKU
4.
aluminum tape. DO NOT use duct tape. Ensure that the
EXTNCB25W
connection is completely sealed.
Remove the tape that is holding the damper closed.
5.
5 Installation
Installation
Installation
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
▶
ON accidentally.
5.1 Installation height
Installation height above cooking surface:
Minimum height: 30" (762 mm)
¡
Suggested maximum height: 40" (1,016 mm)
¡
NOTICE:
Always follow the cooking appliance manufacturer's
installation instructions for proper installation height.
Calculating the optional chimney extension height
Optional chimney extensions are available for purchase in
6" (153 mm) and 18" – 35" (457 – 889 mm) sizes to cover
the space between the top of the hood and the ceiling.
Take the measurements indicated in the following image
at your installation location.
NOTICE:
The hood could incur some damage from heat if a
Thermador Professional® series range or rangetop is
operated with multiple burners at high settings under a
hood that is installed at minimum clearances while the
hood is turned off.
Measure the height from floor to ceiling (A).
1.
Measure the height from floor to cooking surface (B).
2.
Measure the hood mounting height from the bottom of
3.
the hood to the cooking surface (C). Dimension must be
a minimum 30" (762 mm).
Calculate the optional duct cover height (D):
4.
‒
WARNING
D = A – (B + C + 18").
Installation en-us