en-us Installation
Installations require a cutout for the ½" (13 mm)
1.
electrical conduit.
→ "Ceiling cutout", Page 14
X
Optional chimney extension
Note: Follow cooking appliance manufacturer's
recommendations.
Use a T-20 star head screwdriver to remove the screw
2.
securing the junction box channel covering the wires.
16
Remove one circular knockout behind the junction box
3.
channel. Secure a 1" (25.4 mm) strain relief (not
included).
Using two people to lift, rest the hood on the wood
4.
bracket. Make sure the wood bracket fits into the recess
on the back of the hood.
From inside the hood, pre-drill the holes labeled "J" in
5.
the hood into the wood bracket with a ⅝" (16 mm) drill
bit. Secure the hood to the wood bracket with five (5)
1½'' (38 mm) screws.
Connect additional ducting.
6.
5.5 Blower motor installation
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the Ventilation
Planning Guide.
Note: Cutting the plug of the blower will void the warranty
or eligibility for return or exchange.
Installing the integral blower
Integral blower models are integrated into the hood at the
time of installation. Integral blowers should be installed
after the hood is mounted to the wall. For complete
installation instructions, see the instructions supplied with
the blower unit.