AKM Installation | 2 English
2.3.3.1 Connector Options (C)
Pinout for the connector options are listed in chapter "Connector Pinout" from (➜ # 187).
Connector Description
Connector
M40 (Size 1.5)
Power & Brake
Power & Brake
SpeedTec Ready
i-tec
Power & Brake
y-tec
Terminal box
Power & Brake
* Hybrid means: Power and Feedback on the same connector and in one cable
Reference Connector-Motor
PTC*
KTY*
Connection
B
1
2 SpeedTec Ready connectors
C
7
2 SpeedTec Ready connectors
C
1
2 SpeedTec Ready connectors
D**
D**
1 i-tec Hybrid connector
D**
D**
1 Hybrid connector SpeedTec Ready
G
-
2 SpeedTec Ready connectors
1 power connector M40, 1 Feedback
H
1
connector SpeedTec Ready
1 Terminal box, 1 Feedback connector
T
2
SpeedTec Ready
Y
1
1 y-tec connector
* Temperatur sensor PTC or KTY (➜ # 41)
** With connector option D the temperature sensor type depends on the feedback , see (➜ # 39)
38
Kollmorgen | April 2015
Contacts
Usage*
Power/Signal
4 / 2
4 / 4
Feedback
- / 12
Feedback
- / 17
Hybrid
4 / 5
4 / 5
Feedback
- / 12
4 / 2
max. Current [A] max. Cross Section[mm²]
Power/Signal
Power/Signal
75 / 30
30 / 10
- / 10
- / 9
14 / 3.6
1.5 / 0.75
14 / 3.6
1.5 / 0.75
- / 5
150 / 15
Usable with
Position of connection
AKM2
Angular, rotatable, motor mounted
AKM1-AKM2
0.5m cable mounted
AKM3-AKM7
Angular, rotatable, motor mounted
AKM1
Motor mounted
AKM2-AKM6
Angular, rotatable, motor mounted
AKM2-AKM6
Straight, motor mounted
AKM7 & AKM82T Angular, rotatable, motor mounted
AKM8
Motor mounted
AKM1
Motor mounted
Protection
Class
16 / 4
IP65
4 / 1.5
IP65
- / 0.5
IP65
- / 0.5
IP65
IP65
IP65
- / 0.75
IP65
25 / 2.5
IP65