BMP 01-EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
6
Analog interface and switching output (continued)
6.4
Settings using the button
The settings made using the button apply to the
operation using the analog as well as IO-Link
interface.
Normal operation
2 s
Calibration mode
Green 2 Hz
Yellow 2 Hz
Red 2 Hz
1 ×
2 ×
3 ×
4 ×
5 ×
Adjusting the switch point logic
6 ×
7 ×
Fig. 6-6:
Overview of setup mode
16
english
2 s
Adjusting the analog output
Green on/off
Yellow 2 Hz
Red 2 Hz
Range teach minimum
Green off
Yellow off
Red 2 Hz
Range teach maximum
Green off
Yellow 2 Hz
Red off
Adjusting the edge
Green on/off
Yellow off
Red 5 Hz
Teach switch point
Green off
Yellow 5 Hz
Red off
Green on/off
Yellow 5 Hz
Red 5 Hz
Resetting to factory settings
Green 5 Hz
Yellow off
Red off
Legend
Press the
button briefly
Setup error
All LEDs flash for 3 s at 5 Hz
(asynchronous)
Green on = Voltage output
Green off = Current output
Convert: Press the button briefly
Green on = Falling edge
Green off = Rising edge
Convert: Press the button briefly
Green on = Normally closed
Green off = Normally open
Convert: Press the button briefly
2 s
Hold the button
for 2 s
2 s
2 s
2 s
2 s
2 s
2 s
2 s