Before You Call for Service
If the appliance appears to be malfunctioning, read through
this manual first. If the problem persists, check the trouble-
shooting guide below. Locate the problem in the guide and
refer to the cause and its remedy before calling for service.
The problem may be something very simple that can be
solved without a service call. However, it may be required
to contact your dealer or a qualified service technician.
WARNING
!
Electrocution Hazard
• Never attempt to repair or perform maintenance on
the appliance until the main electrical power has been
disconnected. Turning the appliance control "OFF"
does not remove electrical power from the units wiring.
• Replace all parts and panels before operating.
Problem
Appliance not cold enough
(See "Adjusting the temperature" on
page 11)
Appliance too cold
(See "Adjusting the Temperature" on
page 11)
No interior light.
Light will not go out when drawer is
closed
Noise or Vibration
Appliance will not run.
TROUBLESHOOTING
In the unlikely event you lose cooling in your unit, do not
unplug the product from the electric supply, but do call
a qualified service technician immediately. It is possible
that the loss of cooling capacity is a result of excessive
frost build-up on the evaporator cooling coil. In this case,
removing power to the unit will result in the melting of this
excessive quantity of ice, which could generate melt water
that exceeds the capacity of the defrost drain system and
could result in water damage to your home. The end-user
will be ultimately responsible for any water damage caused
by prematurely turning the unit off without appropriately
managing the excess water run-off.
Possible Cause
Control set too warm
Content temperature not stabi-
lized.
Excessive usage or prolonged
drawer openings.
Airflow to front grille blocked.
Drawer gasket not sealing prop-
erly.
Control set too cold
Drawer gasket not sealing prop-
erly.
Failed LED light assembly or light
switch.
Drawer not activating light switch.
Failed light switch
Appliance not level
Fan hitting tube obstruction.
Appliance turned off
Power cord not plugged in.
No power at outlet.
18
CAUTION
!
Remedy
Adjust temperature colder. Al-
low 24 hours for temperature to
stabilize.
Allow temperature to stabilize for
at least 24 hours.
Airflow must not be obstructed to
front grille. See "clearances" on
page 4.
Adjust or replace drawer gasket.
Adjust temperature warmer.
Allow 24 hours for temperature to
stabilize.
Adjust or replace drawer gasket.
Contact a qualified service techni-
cian.
Appliance not level, level appli-
ance, (See page 4, "leveling legs")
Contact a qualified service techni-
cian.
Level appliance, see "Leveling
Legs" on page 4.
Contact a qualified service techni-
cian.
Turn appliance on. See "Starting
your appliance" on page 10.
Plug in power cord.
Check house circuit.