Hyundai N700E Manual De Instrucciones página 88

Tabla de contenido

Publicidad

N700E INSTRUCTION MANUAL
Auto-tuning method
Motor connection
Auto-tuning mode
selection H01=1
Run command ON
Motor parameter setting
Auto-tuning mode
selection H01=1
Note 1. N700E-1600HF/2000HFP ~N7000E-3500HF/3800HFP do not support Expanded Function mode of
H Group
Note 2. The motor parameter of N700E is standard data of HYUNDAI standard 4-poles motor.
At the sensorless vector control when using different poles motor, operates by using auto-tuning
data as a motor parameter.
End display
Auto-tuning process completed :
Auto-tuning process failed :
① DC excitation(no rotation)
② Single phase excitation.
5-24