counter of the measurements is
reset and the wireless connec-
tion is maintained.
Example
L_RESET(1)
Call-up of the auxiliary cycle, counter is reset.
Back to Siemens automated operation [} Page 50]
7.4.
HEIDENHAIN AUTOMATIC OPERATION
The parameters Q1899-Q1940, QR59-QR67 are overwritten during the measurement process. The sub-program collection
comprises standard measurement cycles for the controller Heidenhain iTNC 530 / TNC 640. The sub-program folders must
be saved directly in path TNC:\. The sub-programs are configured for the G17 level. The probe cycles work exclusively with
the XControl.
Cycle
7.4.1.
Probe cycle BSP_L_POS
Probe cycle
Function
BSP_L_POS.H.
The program BSP_L_POS.H is for
determining the position of the
XControl in the machine coordin-
ates system. The reference tool
must be positioned centrally in
the tool axis with a distance of
approx. 5 mm to the contact
point above the XControl. The
two other axes are not travelled
in the probing process.
Example
0
BEGIN PGM BSP_L_POS MM
1
;================================
2
; Calibration tool overall length
3
Q1903 = 5000
4
;================================
5
; M19 / M20 SPINDLE ORIENTATION
6
Q1913 = 19
7
;================================
8
CALL PGM TNC:\X_CONTROL\L_POS.H
9
M30
10
ND PGM BSP_L_POS MM
For the above-mentioned variables, the values from the following table can be used.
Variable
Q1903
Q1913
Link
Note
The program is only required in
the following instances: - When
initially positioning the XControl
in the working area of the ma-
chine. - Each time the XControl is
repositioned in the working area
of the machine.
Value
ℝ≠0
ℤ>0
Program code
BSP_L_POS.H
Meaning
Exact length of the reference tool.
Value for spindle orientation M19 =>
Q1913=19