Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installation,
operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product is
in conformity with the following European Directives: 89/336/EEC and 73/
23/EEC, 98/37/EEC (and subsequent amendments).
1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for
future reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non EEC countries, the
abovementioned standards as well as the current national standards
should be respected in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformationwhich
might occur during use.
• The installation must comply with the provisions set out by the
followingEuropean Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing.
Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on
the automation system, and always request the assistance of
qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
2) GENERAL OUTLINE
The EOS system is compatible with the EElink protocol for fast installation
and maintenance. It is suitable for motorising sectional doors (fig. 3),
protruding fully retracting spring-operated overhead doors (fig. 2) and
counterweight overhead doors provided with an appropriate towing arm
(fig. 4). The overhead door must not be higher than 2.5 metres. Its easy
16 -
EOS - Ver. 07
INSTALLATION MANUAL
installation allows fast fitting without needing the door to be modified. The
irreversible gearmotor keeps the door locked in the closing position.
The SCE control panel is supplied by the manufacturer with standard
setting. Any modification must be set by means of the incorporated display
programmer or by means of UNIPRO. The Control unit fully supports the
EELINK protocol.
These are its main characteristics:
-
Control of a low-voltage motor up to 24 Vd.c.
-
Electronic torque limiter with obstacle detection and torque self-learning
-
Electronic limit switch with encoder
-
Incorporated rolling-code radio receiver with transmitter cloning
-
Presetting for operation by means of local and centralised commands
via wire (SCE-MA S).
The following optional accessories are available:
- CB EOS mod. buffer battery kit.
This allows the automation system to operate even when the mains power
supply is off for a short time.
NOTE: The buffer battery kit is to be installed on the actuator fixing base on
the ceiling side. A minimum distance of 50 mm must be kept between the
fixing base and the ceiling in the case where batteries are expected to be
installed at a later time.
3) TECHNICAL SPECIFICATIONS
3.1) Actuator
Power supply: .......................... 230Va.c. ±10%, 50/60Hz single-phase (*)
Motor voltage: ................................................................................. 24Vd.c.
Max. power absorbed from mains: ....................................................180W
Lubrication: ................................................................... permanent grease
Towing and pushing force: ............................................................... 600N
Working stroke: ..................... 2.60m (extension to 3.60m for PRE1 Mod.)
Average speed: ............................................................................. 5 m/min
Impact reaction: ........................ integrated torque limiter on control panel
Manoeuvres in 24 hours: ...................................................................... 100
Limit switch: .................................................... electronic with self-learning
Courtesy light: ................................................ 24Va.c. 25W max, E14 bulb
Working temperature: ......................................................... -15°C / +60°C
Degree of protection: ......................................................................... IPX0
Total weight: ....................................................................................... 12kg
Noise level: ................................................................................ <70dB(A)
Dimensions: ................................................................................. see fig.1
(*) Available in all mains voltages.
3.2) SCE/SCE-MA/SCE-MA S Control panel (Fig.16)
Supply to accessories: ............................................ 24Va.c. (180mA max)
Torque limiter setting: .......................................... on closing and opening
Automatic closing time: ....................................................... from 2 to 120s
Blinker connection: ........................................................ 24Va.c. max 25W
Service light switching-on time: ........................................................... 90s
Incorporated rolling-code radio receiver: .............. frequency 433.92 MHz
Coding: ............................................... rolling-code algorithm to be cloned
No. combinations: ....................................................................... 4 milliard
Antenna impedance: ........................................................ 50Ohm (RG58)
Max no. radio controls to be memorised: ............................................. 63
Slow-down distance: ............ closing: ~23 cm ............... opening: ~15 cm
4) ACTUATOR INSTALLATION

4.1) Preliminary checks

Check that the door is balanced.
Check that the door slides smoothly along its entire travel.
If the door has not been newly installed, check the wear condition of all
its components.
Repair or replace faulty or worn parts.
The automation reliability and safety are directly influenced by the state
of the door structure.
4.2) Fitting
After unpacking, dispose of the parts which make up the package properly,
by separating the different type of materials (cardboard, polystyrene, PVC,
etc.) according to the national rules in force.
Remove the existing locking bolt from the cremone bolt of the door.
Position joint "G" as shown in fig.6.
Position the half track as in fig. 7, and lower it onto the supporting surface
while tightening the chain/belt to obtain the whole track.
Fit the joint to overlap each of the two half tracks by half its length, as
in fig.8.
Secure the joint by tightening the appropriate screws supplied, as in fig.
9. The door opener is thus ready to be installed.
24Va.c. Vsafe SCE-MA (180mA max)