The burner will not ignite:
The gas valve is not on.
The gas cylinder is empty.
The ignition button doesn't work.
There is no spark on ignition.
The flame of the burner is irregular:
The flame burns inside the burner (whispering sound).
The regulator is defective.
Injector is partially blocked.
Gas leak between joints:
Connections are loose.
The hose is damaged.
The gas valve is faulty.
Connections/joints are damaged.
The pizza stone does not rotate:
The pizza stone does not rotate.
The pizza stone is damaged.
Button/contact or cables are damaged.
TROUBLESHOOTING
Turn on the valve.
Replace the gas cylinder with a new one.
Check the battery.
Contact the service centre
Turn off the burner and let it cool down. Then try to ignite
once more.
Contact the service centre
Clean the injector with a toothbrush. Don't drill out and don't
use wire/steel wire to remove blockages. Contact the service
centre
Tighten loose connections (do not overtighten) and conduct a
pressure leak test using soapy water
(see the instructions 'Leak test' page 4.
Replace the hose. (Contact service centre).
Contact the service centre
Contact the service centre
Make sure that the cable from the power adapter is
connected correctly and that the power is turned on.
Make sure that the batteries are inserted correctly into the
battery compartment.
Check that the batteries are fully charged and replace them
if necessary.
Contact the service centre
Contact the service centre