Gas cylinder connection:
• The gas supply or hose must comply with applicable requirements and must
be regularly examined and replaced as necessary. The hose must comply
with the EN16436 standard. The regulator must comply with the EN16129
standard.
DANGER: Do not use an adjustable pressure regulator (such as the type used
for weed burners). Risk of explosion or combustion.
• The nominal output (gas pressure) should be 37 mbar.
• Worn or damaged hoses should be replaced. Check that the hose is not
squeezed, split or in contact with the pizza oven, excepted at the place
where it is connected.
• In some regions, the hose and regulator may not be supplied with the
appliance.
• The hose for the appliance should not exceed 1.5 m.
• Connect the gas cylinder to the oven using the hose and regulator. Carefully
tighten the nuts, but do not overtighten or twist. Be careful not to get to
damage the regulator fittings. Make sure that ALL valves/buttons on the
oven are on Off-position before opening the gas cylinder.
• The regulator hose must be kept at a distance from sharp objects and heat
sources.
• Before replacing the gas cylinder: make sure the gas is turned off before
disconnecting the hose and regulator from the bottle (not from the oven
itself).
• Replace the flexible hose according to applicable national guidelines.
• Do not use a LPG cylinder that exceeds a maximum width of 310 mm and
570 mm height.
Leak tests: Once the hose and regulator are fitted and secured according to
the instructions, the gas can be turned on. Then spray the joints with a water/
soap mixture to check for any leaks.
NOTE: Make sure the gas cylinder is fully shielded from the oven.
Gas cylinder disconnection:
• When disconnecting gas cylinder: Make sure the oven on/off button is
turned to the OFF position. Make sure the cylinder valve is in the closed
position. Disconnect the regulator assembly from the gas cylinder and
remove it. Be sure to keep the gas cylinder at least one metre from the oven
to avoid risk of ignition.
• Requirements/rules for regulator and hose: the regulator used with your gas
burner oven must be CE-approved and comply with applicable requirements
and regulations.