HANDLING AND INSTALLATION
The appliance is supplied at an operating volt-
age 400V/3N (indicated on the sticker applied
to the dataplate); conversion to 230V/3 can be
carried out as described below.
HAZARD: Before doing any work, cut
off the mains electricity supply.
Pull off the knob (B).
)
Undo the screws (C) remove the control pan-
)
el (D).
Fit the jumper (E) to make the electrical con-
)
nection of the terminals (F).
Change the connections of the terminal
)
board (G) as shown in the diagram.
Replace the lid (D) and fi x it with the screws
)
(C) on completion of the operation.
Close the hatch (B).
)
Remove the test voltage indicator sticker
)
from the dataplate and apply the new one to
identify the voltage being used.
NOTE: On completion of the operation
make sure that there are no malfunctions.
WARNING: Before it is put into ser-
vice, the system must be tested to check the
operating conditions of every single compo-
nent and identify any malfunctions. In this
stage, it is important to check that all health
and safety requirements have been com-
plied with in full.
To test the system, make the following checks:
Check that the mains voltage is the same as
)
that of the appliance.
3395260_inst_GB_rev.1
CONVERSION OF ELECTRICITY SUPPLY
TESTING OF THE APPLIANCE
B
400V/3N
G
230V/3
G
Operate the appliance's circuit-breaker to
)
check the electrical connection.
Check that the safety device is operating cor-
)
rectly.
After testing, if necessary instruct the user in all
the skills necessary for putting the appliance
into operation in conditions of safety, in accor-
dance with legal requirements.