Inlets
The filter system has two inlets with stepped hose adapters.
For connecting a filter pump
For connecting a UVC clarifier (→ Connecting a UVC clarifier)
If an inlet is not used, fit a closed stepped hose adapter.
– The stepped hose adapters are delivered closed.
Prerequisite:
The container is open. (→ Remove the container cover)
The screen holder is hinged up. (→ Hinging the screen holder up/down)
Connecting the filter pump
How to proceed:
1. Shorten the stepped hose adapter to the diameter of the hose used.
– This reduces pressure losses.
2. Insert the stepped hose adapter with flat seal into the inlet opening.
3. Screw the distributor nut with O ring onto the stepped hose adapter and hand tighten.
– BioTec ScreenMatic² 145000: Alternatively you can fit a 50 mm hose sleeve.
4. Slip the hose clip over the hose, fit the hose onto the hose connector and secure with the
hose clip.
52