System messages
LED
Malfunction
Flashes
No automatic
green/red
cleaning cycle
within 48 hours
No flow of wa-
ter
No water de-
tected by the
sensor
Flashing red 20 automatic
cleaning cycles
in succession
Flashing
ScreenMatic
green
screen not ro-
tating although
a manual clean-
ing cycle was
triggered.
Off
ScreenMatic
screen not ro-
tating although
a manual clean-
ing cycle was
triggered.
62
Possible cause
Sensor soiled
No dirty water, cleaning is
not necessary
Filter pump is not operating Start up the filter pump.
Control device incorrectly
positioned
Control device defective
Insufficient conductivity of
the water
Insufficient pump capacity
ScreenMatic screen soiled
Sensor soiled
Control device incorrectly
positioned
Pump capacity too high
Motor cable plug not con-
nected or incorrectly con-
nected to the control device
Motor defective
Connection cable plug not
connected or incorrectly
connected to the trans-
former
Transformer not connected
to the mains voltage
Transformer defective
Control device defective
Remedy
 Clean the sensor.
 Descale the sensor.
Correctly position the control
device
Replace the control device.
Increase the water hardness
with OptiPond
Adjust the pump capacity ac-
cordingly
 Start manual the cleaning
cycle and use a brush to
clean the ScreenMatic
screen on the side of the
water distributor
(→ Manual cleaning)
 Clean the ScreenMatic
screen from the inside if
the mesh is clogged by a
biofilm
(→ Cleaning/replacing the
ScreenMatic screen)
Clean the sensor.
Correctly position the control
device
Adjust the pump capacity ac-
cordingly
Connect the plug, check that
it is correctly seated.
Replace motor
Connect the plug, check that
it is correctly seated.
Connect the transformer to
the mains voltage.
Replace transformer
Replace the control device.
Reset the sys-
tem message
Automatic reset
after remedy of
malfunction
Automatic reset
after remedy of
malfunction