Descargar Imprimir esta página

cozze 90354 Manual De Usuario página 11

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
and regulator switch to the 'OFF' position. Wait 5 minutes before attempting to relight
the appliance. If the problem persists after relighting, consult your gas dealer, or the
store where you purchased the pizza oven, or a qualified gas engineer for assistance or
repair. Never try to rectify the problem yourself as this could result in serious injury and/
or property damage.
Clean the appliance of excess fat, before storage, with a damp cloth using a mild
detergent solution as the cleaning agent.
Store the appliance in a clean dry environment.
Do not store your gas cylinder indoors. Store in a well ventilated area away from direct
sunlight.
CONNECTING THE GAS CYLINDER TO THE APPLIANCE
Connect the hose and regulator assembly to the LPG cylinder. Only use a CE-approved
regulator and hose with a ¼" connector.
Carry out a leakage test using soapy water before using the heater.
TO CHECK FOR LEAKS
Make 2-3 fluid ounces of leak detecting solution by mixing one part washing up liquid
with 3 parts water.
Ensure the control valve is "OFF".
Connect the regulator to the cylinder and ON/OFF valve to the burner, ensure the
connections are secure then turn ON the gas.
Brush the soapy solution on to the hose and all joints. If bubbles appear you have a leak,
which must be rectified before use.
Retest after fixing the fault. Turn OFF the gas at the cylinder after testing.
If detected leakage can not be rectified, change the regulator and hose.
In the event of gas leakage, turn off the gas supply.
REGULATOR AND HOSE
Use only regulators and hose approved for LPG at the above pressures (See technical
information). The life expectancy of the regulator is estimated as 10 years. It is
recommended that the regulator is changed within 10 years of the date of manufacture.
The use of the wrong regulator or hose is unsafe; always check that you have the correct
items before operating the appliance.
The hose used must conform to the relevant standard for the country of use. The length
of the hose must be 1.5 meters (maximum). Worn or damaged hose must be replaced.
Ensure that the hose is not obstructed, kinked, or in contact with any part of the pizza
oven other than at its connection.
The hose should comply with the standard EN16436.
The hose should not be twisted or kinked when attached to the gas cylinder.
Flexible metal or rubber pipe, used to connect the appliance with the LPG cylinder must
be changed within the prescribed intervals and according to the National Rules in force.
11