INSPECTION AND MAINTENANCE
3. Connect a water hose. Turn on the
water and adjust the flow.
Continue flushing the outboard motor
for 3 to 5 minutes
4. After the flushing, be sure to reat-
tach the flushing connector cap.
5. Tilt up the outboard motor.
.
1. Hose joint
ENOM00085-A
Flushing by test tank
ENOW00081-0
Do not start engine without removing pro-
peller, or accidentally turning propeller
could cause personal injury.
10
ENOW00082-0
Never start or operate the engine indoors or
in any space which is not well ventilated.
Exhaust gas contains carbon monoxide, a
colorless and odorless gas which can be fatal
if inhaled for any length of time.
ENOW00036-A
When the engine is started in the test tank,
to avoid over heating and water pump dam-
1
ENOF01115-0
WARNING
WARNING
CAUTION
age, be sure the water level is at least 10 cm
(4 in.) above the anti ventilation plate.
And be sure to remove the propeller, when
starting the engine in the test tank. (See
page 72)
Run the engine only at idling.
3
2
1. Test tank
2. Water
3. Over 10 cm (4 in.)
ENOM00950-0

Fuse replacement

ENOW00923-0
CAUTION
Before replacing a fuse, disconnect the bat-
tery cable from the battery negative (-) ter-
minal. Failure to do so may cause a short-
circuit.
ENOW00924-0
CAUTION
Never use a fuse with a rating that exceeds
the specified rating as this could cause seri-
ous damage to the electrical system.
If a blown fuse is detected, try to deter-
mine the cause for this and correct it. If
the cause for the problem is not cor-
rected, the fuse will likely blow again.
If the fuse continues to blow, request an
authorized Tohatsu dealer to inspect
1
ENOF00863-0

Publicidad