6.3.5. CT Connection
CT Connection Instructions:
1.
Loosen the swivel nuts of the cable glands on the COM connection cover of inverter,
and unscrew the 4 screws on the corners, then you will see the grid CT, PV CT and meter
communication ports. Keep the screws on the cover.
2. Locate the included Grid CT and PV CT.
3. Lead the CT cable through the cable gland of the COM connection cover, don't tighten the
swivel nuts of the cable glands.
4. Insert the RJ45 plugs to the relative RJ45 sockets.
5. Buckle the magnetic snap of the Grid CT on the house-service live cable. The arrow on the
magnetic snap of the Grid CT should point to the grid port of inverter.
6. For hybrid or AC-coupled storage system application, buckle the magnetic snap of the PV
CT on the live cable of the installed PV inverter. The arrow on the magnetic snap of the PV
CT should point to the mains grid.
7.
Connect the CT cables to the Grid CT and PV CT respectively.
TIP
© 2023 Maxeon Solar Technologies, Ltd. All rights reserved. | 547143 Revision B - June 2023
Specifications included in this document are subject to change without notice
1
2
3
4
Grid-CT
PV-CT
The CT cable marked Grid CT should be connected to the Grid CT, and the
CT cable marked PV CT should be connected to the PV CT.
PH2x150mm
2.5Nm
37