to enter the wheel geometric data with the keypad, disabling control of the automatic sensor.
Return the sensors to the correct position.
➥
The automatic arm laser line does not work (if present)
To replace the battery, proceed as follows:
Remove the four screws in the le-
➥
ver (A, Fig.329) and then remove the plastic
casing (B, Fig.29)
Pull out the card (C, Fig.29) inside
➥
Replace the battery in the card
➥
with a new CR2450 3V;
Continue to mount the lever in the
➥
opposite direction to disassembly.
CAUTION
Pay attention to the positioning of the cables
inside the lever groove to prevent acciden-
tally damaging the cable while closing the
plastic crankcase.
If the laser line does not work with the new battery, call for technical assistance.
Pressing the START key and the button (only the START key if the guard
is installed) the wheel does not spin (the machine does not start)
For machines with guard, check that it is not raised (the message "A Cr" appears).
Lower the wheel guard.
➥
For machines without guard, check that both the START key as well as the key on the side of the
machine have been pressed.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
Repeat the spin, taking care not to disturb the machine while measuring is in progress.
➥
The machine does not firmly rest on the floor.
Make sure that the floor support is firm
➥
The wheel is not locked correctly.
Tighten the securing ring nut correctly.
➥
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
Repeat the spin, taking care not to disturb the machine while measuring is in progress.
➥
The machine does not firmly rest on the floor.
Make sure that the floor support is firm.
➥
The wheel is not locked correctly.
Tighten the securing ring nut correctly.
➥
The machine has not been calibrated correctly.
Carry out the sensitivity calibration procedure.
➥
The entered geometric data are not correct.
Check that the data corresponds to the dimensions of the wheel and correct, if necessary.
➥
Perform the width sensor calibration procedure.
➥
EM 9250 - EM 9250 C CompactLine Operator's manual
29
UK
145