Fault diagnostics for "SOLID" Electronic Control Unit

( FROM SERIAL NUMBER "206498 GO 531T", "206742 GO 552T - 562T" )
Code
Description
TERMICO SPAZZOLE
NONE
(BRUSHES THERMAL)
SWITCH)
ERRORE_SD_TRZ
- 1
(DR_SD_ERROR)
ERRORE_SD_SPZ
- 2
(BR_SD_ERROR)
ERRORE_SD_ASP
- 3
(VC_SD_ERROR)
ERRORE_TEMPERATURA_MAX
- 20
(MAX_TEMPERATURE_ERROR)
ERRORE_MOTORE_SCOLLEGATO
- 27
(DISCONNECTED_MOTOR_ERROR)
ERRORE_FILIPOT
- 30
(PW_ERROR)
ERRORE_I2T_TRZ
- 40
(DR_I2T_ERROR)
ERRORE_I2T_ASP
- 50
(VC_I2T_ERROR)
ERRORE_I2T_SPZ
- 60
(BR_I2T_ERROR)
ERRORE_STANDBY
- 70
(STANDBY_ERROR)
ERRORE_BATT_MIN
- 80
(MIN_BATT_ERROR)
ERRORE_BATT_MAX
- 90
(MAX_BATT_ERROR)
ERRORE_SGL_STOP_SPZ
- 120
(BR_STOP_THR_ERROR)
ERRORE_SGL_STOP_ASP
- 130
(VC_STOP_THR_ERROR)
ERRORE START
- 140
(START_ERROR)
Action
The message INTERVENTO TERMICO SPAZZOLE (BRUSHES THERMAL SWITCH TRIPPED) is displayed. The
diagnostics led starts blinking. The brushes stop.
SHUT DOWN TRAZIONE (DRIVE SHUT DOWN). All motors are stopped. The machine must be power cycled.
An error code is displayed. The red led starts blinking.
SHUT DOWN SPAZZOLE (BRUSH SHUT DOWN). All motors are stopped. The machine must be power
cycled. An error code is displayed. The red led starts blinking.
SHUT DOWN ASPIRAZIONE (VACUUM SHUT DOWN). All motors are stopped. The machine must be power
cycled. An error code is displayed. The red led starts blinking.
This error occurs when the board temperature (detected via the drive temperature adc input) exceeds the
threshold set in the MAX_TEMP parameter. The motors stop and the machine must be power cycled. An
error code is displayed. The red led starts blinking.
This error is indicated when upon switching on the machine the drive motor is disconnected or not pro-
perly connected. The machine must be power cycled. An error code is displayed. The red led starts blinking.
This error is indicated when the speed potentiometer adc value exceeds the value set in the SOGLIA_IN-
TERR_FILIPOT1 (THR_INTERR_FILIPOT1) parameter for more than T_ERR_INTERR_FILIPOT milliseconds. An
error code is displayed. The red led starts blinking.
Drive I2T. All motors are stopped. The machine must be power cycled. An error code is displayed. The red
led starts blinking.
Vacuum I2T. All motors are stopped. The machine must be power cycled. An error code is displayed. The
red led starts blinking.
Brushes I2T. All motors are stopped. The machine must be power cycled. An error code is displayed. The
red led starts blinking.
This error is signalled when the time indicated (in minutes) in the T_STANDBY parameter has elapsed and
no operation has been executed on the machine. The machine must be power cycled. An error code is
displayed. The red led starts blinking.
When the battery tension (understood as a mean value) falls for more than 2 seconds below the value
included in the BATTERIA_MIN_PB (MIN_LD_BATTERY) parameter (in case of lead batteries) or in the BAT-
TERIA_MIN_GEL (MIN_GEL_BATTERY) parameter (in case of GEL batteries), the motors stop, the battery
value does not increase enough to exceed the threshold and the machine must be power cycled. When
the battery value reaches 10%, the battery icon and the indication of the percentage value start blinking.
When the value drops below 10%, the percentage value is replaced by the indication LOW. When the
battery value falls below its minimum, the error code is displayed on top, while an X and the indication
LOW are displayed at the bottom to signal that the battery is dead. The battery icon and the red led blink
simultaneously.
When the battery tension (understood as a mean value) exceeds the value included in the BATTERIA_
MAX_PB (MAX_LD_BATTERY) parameter (in case of lead batteries) or in the BATTERIA_MAX_GEL (MAX_
GEL_BATTERY) parameter (in case of GEL batteries), the motors stop and the machine must be power
cycled. Before the error is signalled, the vacuum motor is turned on to try to reduce the battery tension.
If the tension remains above the threshold, the error is signalled. An error code is displayed. The red led
starts blinking.
When the battery tension (understood as a mean value) falls for more than TEMPO_SOGLIA_3 (3_THR_
TIME) milliseconds below the value included in the SOGLIA3_BATT_PB parameter (in case of lead batteries)
or in the SOGLIA3_BATT_GEL (GEL_BATT_3THR) parameter (in case of GEL batteries), the brushes motor
stops. The battery value does not increase enough to exceed the value set in the threshold parameter. The
lead of the brushes button starts blinking until the brushes stop. The red led starts blinking. The informa-
tion concerning battery and hour meter will still be displayed.
When the battery tension (understood as a mean value) falls for more than TEMPO_SOGLIA_4 (4_THR_
TIME) milliseconds below the value included in the SOGLIA4_BATT_PB parameter (in case of lead batteries)
or in the SOGLIA4_BATT_GEL (GEL_BATT_4THR) parameter (in case of GEL batteries), the vacuum motor
stops, together with the brushes motor. The battery value does not increase enough to exceed the value
set in the threshold parameter. The led of the vacuum button starts blinking until the vacuum stops. The
red led starts blinking. The information concerning battery and hour meter will still be displayed.
This error is signalled when upon switching on the machine one of the forward or backward inputs is
active. When the error is fi xed, the machine starts. An error code is displayed. The red led starts blinking.