A
B
C
D
E
F
G
H
I
K
M
N
O
P
Q
R
S
T
U
V
6-62
136
"BALANCE WITH RUNOUT"
K) Excludes the Pull reading, in order to optimise
the operating times, when this information is not
required. The function must be enabled when
operating the advanced function "Set of Wheels".
Set as "Disabled" to cancel the Pull reading
during the run. Preset value: Enabled.
M) Allows selection of RIM ONLY advanced
diagnosis. Select "Enabled" = Enables RIM
ONLY advanced diagnosis. Select "Disabled" =
Enables automatic switching to the MATCHING
procedure if the machine detects the presence of
the rim only.
N) Limit (threshold) for RIM ONLY peak to peak
radial Runout. Preset value: 0.7 mm.
O) Limit (threshold) for RIM ONLY first harmonic
radial Runout. Preset value: 0.5 mm.
P) Limit (threshold) for RIM ONLY peak to peak
lateral Runout. Preset value: 0.7 mm.
Q) Limit (threshold) for RIM ONLY first harmonic
lateral Runout. Preset value: 0.5 mm.
R) Enables/Disables the Find Flat Spot option. This
function detects flattening of the tread. If flat
spots are detected, an alert message appears in
the Optima Access screen page.
S) Enables/Disables the display of WARNINGS
regarding dips in the side of the tire. The faults
in the side of the tire are highlighted with a
colorimetric diagram during the 3D display.
T) Enables/Disables the screenpage that shows the
multiple position Runout calculation.
U) Enables/Disables the display of an analysis of
the three Runout harmonics.
V) Enables/Disables the RFV (Radial Force
Vectoring) calculation.