Descargar Imprimir esta página

JAROLIFT TDEF Serie Instrucciones Originales página 35

Ocultar thumbs Ver también para TDEF Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
ATTENTION!
All work on electrical equipment carries the risk of fatal injury from electric shock!
Connecting the tubular motor to the mains and any work on electrical equipment must only
be carried out by an approved electrical specialist in accordance with the respective connec-
tion plans of the device. Carry out all installation and connection work in a voltage-free state.
Connection plan – motor with electronic limit switches and integrated radio receiver.
Black
Gray
1-pole push-
button
(optional)
L1
N
PE
Optionally, you can operate the TDEF radio motors with an additional
pushbutton (control lines B1 and B2).
Only use 1-pole 1-phase pushbuttons for this purpose.
These are available at www.jalousiescout.de.
The motor is controlled – independently of the radio transmitter –
in a sequence of steps (up-stop-down-stop, etc.).
ELECTRICAL CONNECTION
ATTENTION!
No external voltage
may be applied to
the control cables B1
and B2!
If you do not con-
nect a pushbutton,
insulate the gray and
black control cables
(B1 and B2) INDIVID-
UALLY with Wago or
luster terminals.
B1
B1
Control cable (black)
B2
B2
Control cable (gray)
L1
L1
Phase (brown)
N
N
Neutral cable (blue)
PE
PE
Protective earth (green-yellow)
35