3.2.
REVERSING DOOR procedure
We ONLY supply the necessary components at the customer's request.
The Reversing door kit (code 12118066) contains:
1 auxiliary cable for the reversing door (code 12101701)
1 bushing (code 12101703)
2 insertable flanges (code 12101702)
Assembly process:
1. Remove the top cover by undoing the 4 "A" bolts with a No 3 Allen key in order to access the reed sensor
terminal of the door (upper right section) from above. See Fig. 1.
2. Disconnect the reed sensor terminal of the door. See Fig. F.
3. Remove the front cover by undoing the 6 "B" bolts and open the door to access the 2 "B1" bolts. Use a No 3
Allen key. IMPORTANT: do not try to remove the 2 "C" bolts.
4. After the front cover has been removed, remove the 2 "C" bolts that are secured with a nut at the back and
insert them in the holes where the 2 "B1" bolts were. These bolts serve to "plug" the 2 holes making the
door reversible.
5. Insert the new cable (supplied), following the layout shown in Fig. 2 of the next page. There is a hole in the
air box for the cable to pass through. Remove the existing plug and insert the bushing (supplied) in its
place. Remove the filter cover to make access easier and insert the cable more easily.
Fig. F
Fig. F
fig.1
64