PROGRAM: With the cursor on PROGRAM, use the INC () and DEC (), keys to move from
one programme to another (there are 9 programmes) and use the SELECT key to confirm the
programme to be selected and the cursor moves to TEMP.
TEMP: With the cursor on TEMP, use the INC () and DEC () keys to modify the temperature of
the previously selected programme. Use the SELECT key to confirm the change in the
temperature and the cursor moves to the next option, TIME.
TIME: With the cursor on TIME, use the INC () and DEC () keys to modify the time of the
previously selected programme. Use the SELECT key to confirm the change in the time and the
cursor moves to the next option, AG. TIME.
AG. TIME: With the cursor on AG TIME, use the INC () and DEC () keys to modify the time the
dryer takes to reverse the direction of the drum rotation. Use the SELECT key to confirm the
change in the time and the cursor moves to the next option, HUMIDITY. Values below 50" should
not be entered.
HUMIDITY: With the cursor on HUMIDITY, use the INC () and DEC () keys to modify the
relative humidity of the previously selected programme. Mediante la tecla SELECT, se confirmará
el cambio de la humedad relativa realizada, y el cursor pasará a la siguiente opción que es
COOL TIME.Se recomienda un valor entre 15 – 35 % H.R.
IMPORTANT NOTE: If the value entered is equal to 0, then the programme in question will
operate with time so that the dryer will end the cycle at the end of the time selected in the
programme and will not use the humidity sensor.
COOL TIME: With the cursor on COOL. TIME, use the INC () and DEC () keys to modify the
cooling time required on completion of the drying cycle of the previously selected programme.
Press SELECT to confirm the modification to the cooling time.
To exit the counter menu, press PROG while in the user menu, and with the cursor over
EXIT, press SELECT to exit the technician's menu and go to the main Programme menu.