CONFIGURATION MENU
Navigation :
1 Press the MODE button for 3 seconds to access the Configuration Menu
2 Use the arrows to scroll through the different parameters
3 Press the SELECT button to select the parameter or enter the submenu.
4 When a parameter is flashing, use the arrows to change its value
5 Confirm the parameter value by pressing SELECT again
Languages :
Selecting the display language.
Sound:
Turning the unit's sound on (ON) or off (OFF).
Auto-Restart:
Enable (ON) or disable (OFF) the AUTO-RESTART function. This function automatically restarts the charger in the event of a power
failure.
Auto-Detect :
Enable (ON) or disable (OFF) the AUTO-DETECT function. This function automatically starts a charge when a battery is connected
to the charger.
Date :
Setting the date and time.
Cable calibration :
Procedure for calibrating the charging cables of the device, so that the charger optimally compensates for the voltage drop due
to the cables. It is strongly recommended to perform this procedure at least once a year and each time the charging cables are
replaced.
Calibration procedure :
1 Press SELECT to enter the CABLE CALIBRATION submenu
2 Short-circuit the clamps
3 Press START/STOP to start the calibration
: The calibration was successful.
4
Err19: Cable_NOK : A problem occurred during cable calibration.
Check that the cables are in good condition and correctly short-circuited and repeat the operation.
GYSFLASH CNT
Ensure that the metal parts of the jaws to which the cables are attached are in good
contact with each other.
OK
NOK
EN
NOK
21