Plantillas de Vitrocerámica
Remember that the connection wire should match the connection type and the
power rating of the ceramic hob.
The connection cable must be secured in a strain-relief clamp.
WIRING DIAGRAM
Warning! Remember to connect the safety circuit to the connection box
terminal marked with
must have a safety switch which enables the power to be cut off in case
of emergency. The distance between the working contacts of the safety switch
must be at least 3mm.
Before connecting the ceramic hob to the power supply, it is important to read
the information on the data plate and the connection diagram.
Warning!
Remember to connect the safety circuit to the connection box terminal marked
with
.
Read the information on the data plate and the connection diagram before
connecting the ceramic hob to the power supply.
⚫ The cable connections must follow the diagram located on the bottom of
the hob.
⚫ Carefully tighten all the terminal screws using a good-quality screwdriver.
⚫ If all the zones are not working the first time the hob is powered, check
that all terminal screws are tight before contacting the Customer Care
department.
⚫ IMPORTANT: Do NOT connect the appliance to the main supply through a
13A plug and socket.
⚫ This appliance must be wired into a 30 A double pole switched fused spur
outlet, having 3 mm contact separation, and placed in an easily accessible
position adjacent to the appliance. It should not be above the appliance
and no more than 1.25m away from it.
⚫ If required, the cable can be looped, but make sure it is not kinked or
trapped when the hob is in position. It should not be in contact with hot
parts of the appliance.
Replacing the main supply cable
If the main supply cable is damaged, replace it with an appropriate spare.
. The electricity supply for the ceramic hob
www.derkochline.com