UPS
Deceleration torque (not avail-
able for hydraulic bollards)
E iting the menu/saving
Description of level 2 para eters
·
: Request for maintenance
- : the request for maintenance is not active.
- : after the programmed cycles set by the counters and , the programmed output is activated (see parameters ,)
- : after the programmed cycles set by the counters and , the programmed output is activated (see parameters ,) and
the bollard lights fl ash twice.
-
·
: Programming maintenance cycles in thousands and millions
These two parameters set the number of cycles after which a request for maintenance is signalled.
Thousands of cycles can be set with the parameter, millions of cycles with the parameter. E ample: to set maintenance alarm
after 275 000 cycles, set to . and to .
·
: Closing limit switch presence.
This parameter must be set only for bollards with additional limit switch installed for closed-fully up position. After every default
operation it is set to for and bollards, for the others.
=
=
·
;
: Assistance required
If confi gured, the contact indicates that the electronic control unit detected an error in the automation and in particular, the failure
of the travel stop or the solenoid valve (hydraulic bollards only). The error is also signalled by the triple fl ashing of the cover lights, if
installed
·
: TERMON (integrated electronic motor heating system)
Should be activated ONLY when the ambient temperature where the bollard is installed drops below a minimum of 0°C for all the
day.
= , TERMON is disabled (default)
= , minimum heating
= , ma imum heating
·
: Deceleration torque (electromechanical bollards only)
Sets the deceleration speed at the end of the closing manoeuvre.
The value of the deceleration speed at the end of opening is factory preset and cannot be modifi ed.
The following table gives the 3rd level functions and the adjustable parameters.
= DEFAULT value set in factory.
Par.
Function
PDM dynamic input polarity
Limit switch connection
Pressure switch polarity (for
hydraulic bollards only)
EFO Pressure switch polarity
Input AUX polarity
Output 4 polarity
Output 5 polarity
Commands accepted during pause
time
Control unit
: disabled
: enabled, opens automatically during mains failure
: enabled, closes automatically during mains failure
WARNING:THIS SELECTION MAY BE DANGEROUS
Pressing the "F" key e its the programming menu and changes are saved
8.4
PROGRAMMING
3rd LEVEL
: input N.O.
: input N.C.
: series (N.O. 2-wire sensors)
: parallel (N.C. 3-wire sensors)
: N.O. (used until 2012)
: N.C. (used from 2013)
: N.O.
: N.C.
: N.O.
: N.C.
: N.O.
: N.C.
: OFF
: ON
- 37 -
= parameter value set during installation: should be fi lled if
DEFAULT value is modifi ed.
Settable data