This solution is recommended when you want to allow entry to a reserved area, without using any commands, allowing transit of vehicles in
just one direction.
Loops S1 and S2 also have a safety function in that they will not let the bollard to ove all the ti e if the vehicle is over S1 or S2.
- Connect the N.O. contact of the coil receiver S1 to the OPEN input.
- Connect the N.O. contact of the S2 loop receiver to the CLOSE input.
- The dimensional values given are only appro imate.
*
We suggest installing the "RME 2" metal mass detector.
PARAMETER





Control unit
INSTALLATION B
13.2
RECOMMENDED DIMENSIONS
DATA
DESCRIPTION

The close command acts as a close-when-released and safety function.

Radio channel 1: Disabled

Opening consent

Semiautomatic logic

Command during pause is OFF
AUTOMATIC ENTRY OR EXIT
- 43 -
EN
The vehicle approaches the
reserved area. When over the
loop S1, the bollard goes down.
When the vehicle is no longer
over loop S2, the bollard will
rise again.