2.4.Tips and advice on installation
2.4.1.Questions about the product?
Observations
The motorised product does not
operate.
The motorised product stops too soon. The crown is incorrectly positionned.
2.4.2.Re-setting the end limits
NOTICE
Only available for end limits set in manual mode.
1] Position the motorised product at the end limit to be readjusted.
2] Press the Up and Down buttons simultaneously until the motorised product
moves up and down.
3] Press the Up or Down button to move the motorised product to the new
desired position.
4] To confirm the new end limit, press the my button until the motorised
product moves up and down.
2.4.3.Replacing a lost or broken Somfy control point
NOTICE
This reset deletes all the local control points, however the sensors, end limit settings and favourite position (my) are
retained.
14
Possible causes
The battery is discharged.
The wiring is incorrect.
The control point battery is low.
The control point is not compatible.
The control point used has not been
programmed into the drive.
The end limits have been incorrectly set. Readjust the end limits, referring to Re-
Solutions
Refer to the battery instructions guide.
Check the wiring and modify it if
necessary, referring to Wiring [} 6].
Check the battery and replace it as
required.
Check the compatibility and replace the
control point if necessary.
Use a programmed control point or
program this control point, referring to
Programming the control point
[} 11].
Fit the crown correctly, referring to
Assembly [} 5].
setting the end limits [} 14].
1]
2]
3]
4]
©