Function
AC Voltage
(V AC)
DC Voltage
(V DC)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
Frequency Range: 50 to 60Hz
Function
Resistance
Maximum Input: 600V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
• Diode Test: Max. 1.5mA, open circuit voltage ~3.0V DC
• Continuity Check: Audible signal <50Ω, current <0.35mA
• Sampling Frequency: 3 samples per second
• Auto Power off: After ~30 minutes of inactivity.
• Overload: "OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
• Polarity: "-" on display indicates negative polarity
• Display: 3-5/6 digit, 6000 Count LCD
ELECTRICAL SPECIFICATIONS
Range
6.000V
60.00V
600.0V
1000V
600mV
6.000V
60.00V
600.0V
1000V
60.00A
600.0A
Range
600.0Ω
6.000KΩ
60.00kΩ
600.0kΩ
6.000MΩ
60.00MΩ
Resolution
Accuracy (50/60 Hz)
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
10mA
100mA
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
±(1.5% + 5 digits)
±(1.2% + 5 digits)
±(1.5% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(1.2% + 3 digits)
±(2.0% + 8 digits)
±(2.0% + 5 digits)
Accuracy
±(1.5% + 5 digits)
±(2.0% + 10 digits)
3