Descargar Imprimir esta página

Promax PROLINK-4 Manual De Instrucciones página 188

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 35.- Calibrate function selection for Sat IF Test.
2.- MEASUREMENT OF THREE PILOTS THROUGHOUT THE NETWORK
Once PROLINK-4 has been calibrated, connect the RP-050 to the point where
it will be connected the satellite dish (signal source) and start to take level
measurements in the different distribution outlets using the PROLINK-4. On the screen
will appear the attenuation values for the three pilot frequencies measured in the outlet
plug (see the following figure).
Figure 36.- Attenuation measurements in a plug.
In order to finish of measuring, press the rotary selector [4] and select from
FUNCTIONS menu the End Test option.
Page 70
FU N C TIO N S
C A L IB R AT E
E N D T E S T
B AT T E R Y & L N B
D I S E q C
N E X T
10
FU N C IO N ES
0
-10
-20
1050.0 MHz
1575.5 MHz
REF.
90.0 dBuV
78.0 dBuV
PLUG
12.0
ATT.
USER'S MANUAL. PROLINK-4
1/2
2100.0 MHz
91.0 dBuV
90.5 dBuV
74.3 dBuV
65.0 dBuV
16.7
25.5
02/2003

Publicidad

loading