Problem
The squeegee does not dry
The detergent solution does not come down evenly
on the brushes.
The detergent solution does not come down or only
a small amount comes out on the brushes
The machine does not clean well
the machine does not start
The machine does not start or it stops suddenly
NOTE
!
Never use fuses of a higher value, you risk causing damage to the system. If the fuses blow repeatedly, this means the machine has a defect. Contact
an AUTHORISED SERVICE CENTRE.
TROUBLESHOOTING {1/2}
Cause
Worn squeegee rubber blades
Squeegee clogged
A foreign object has become wedged in the
squeegee
Vacuum hose clogged
Squeegee poorly adjusted
Water drain hose cap open
Vacuum motor blown
Vacuum motor brushes worn
Squeegee not lowered at start-up, faulty actuator.
Dirty water vacuum fi lter, clogged
Recovery tank cover gaskets, damaged
Water supply hoses on the brushes, clogged
Water supply hoses on the brushes, clogged.
Water supply hoses on the brushes, crushed.
Water fi lter (solution) clogged
Water fi lter (solution) not perfectly closed
Blocked closing electromagnet
No water in the tank
Water pump
Brushes badly worn
Brushes unsuitable for the type of fl oor
Detergent not suitable
Poor brush pressure on the fl oor
High operating speed
The main ignition key has not been inserted
The batteries are low
Blown fuse
Safety micro-switch under the seat, broken
Emergency stop button, pressed
Anti-tear relay for battery charger, damaged
Battery connection plug not inserted
Batteries disconnected
Batteries low
Motors under enough stress to trip the thermal mag-
netic protection.
The operator got up and the micro under the seat
has cut off the power to the system.
Anomaly, alarm on the display
< continued on the next page >
80
Solution
Replace the rubber blades
Clean the squeegee
Remove the foreign object
Clean the hose
Adjust the tilt angle (see "MAINTENANCE {FIG.12 - 3/4})
Close tightly
Replace the motor
Replace the brushes
Replace the actuator
Clean the fi lter (see WATER DRAINING AND CLEAN-
ING THE RECOVERY TANK {FIG.10}).
Replace gaskets
Clean piping
Clean piping
Restore hose or replace
Clean fi lter
Check the perfect tightness of the water fi lter
Replace the electromagnet
Fill the water tank
Check water pump operation
Replace brushes
Use suitable brushes
Replace detergent
Adjust pressure
Decrease speed
Insert key and turn clockwise
Check the charge level and charge them, if necessary
Check and replace the fuse, if necessary
Read NOTE!
Replace the micro-switch
Disconnect and repeat the machine start-up proce-
dure (see STANDARDS FOR SCRUBBER COMMIS-
SIONING).
Replace relay
Connect plug
Connect batteries
Charge the batteries
Wait for about a minute and then repeat the start-up
procedure.
Sit and press the accelerator pedal
see ELECTRICAL SYSTEM {FIG.17 - 4/6} - CONTROL
UNIT ALARM DIAGNOSTICS TABLE