4
Installation
4.1
General notes
ModulA is only intended for installation indoors. The pumps must be mounted voltage-free so that
no energy can be transferred from the pipes to the pump casing. The pumps can be installed di-
rectly in the pipe, provided the pipes are designed for the weight of the pump.
Installation is only possible after completion of all welding and soldering work on the system. Avoid
drops of water on the pump motor, especially the frequency converter.
Warning
The local regulations for the lifting and carrying
of loads must be adhered to. The weight of the pump is given on the packaging.
4.2
Flushing heating equipment (for extended pump)
To avoid unwanted interruptions to operations and non-running of the pump after longer
periods of inactivity, we recommend thoroughly flushing out the equipment following the
new installation or adaptation of heating and refilling.
The equipment must correspond with the latest technology. (Placement of expansion vessel
or safety flow).
4.3
Installation
Install only after completion of all welding or soldering work on the equipment. Water drops should
be avoided on the pump motor, especially on the electronics. The pump casing should be installed
voltage-free in the equipment.
4.4
Permissible installation positions
The installation position of the rotor shaft must always be horizontal.
961869_01
Werkstoff:
ModulA BG2
Motor waagrecht
für BA
Biral AG
CH-3110 Münsingen
english
Massstab
Dokumentstatus:
1:2
Freigegeben
Format:
05.12.2019
sta
A3
Erstelldatum
05.12.2019
sta
PDM_Nr:
203246
Zeichnungsnummer
Änd. Ind.
961869
01
A
Rev.
Vers.
13
|