Battery: removal
! ATTENTION: the operation of removing the batteries
must be carried out by a skilled technician.
!
following precautions:
Contact with the skin can cause irritation; wash
with soap and water.
Inhalation of vapours can cause irritation to the
airways; stay out in the open air and consult
a doctor.
Contact with the eyes can cause irritation;
for at least 15 minutes, and consult a doctor.
! DANGER: When removing the batteries, the
skilled technician must wear the Personal
Protective Equipment (gloves, eyewear,
overalls, etc.) needed to limit the risk of
accidents; remove the ignition key from the
control panel before proceeding with the
removal operation, keep away from naked
do not generate sparks and do not smoke.
! ATTENTION: when removing the batteries, ensure
that the battery charger is unplugged from the power
socket.
! ATTENTION: before carrying out the operations
apply the parking brake.
-
Disconnect the terminals of the battery cables
from the battery poles.
-
to the base of the machine.
-
Lift the batteries from the compartment using
suitable handling equipment.
Replacing the centre brush
! ATTENTION: before carrying out the operations
apply the parking brake.
To replace the centre brush, proceed as follows:
-
Unscrew the knobs and open the door on the left
of the machine.
-
Unscrew and remove the three knobs securing
the brush compartment cover.
-
Remove the cover of the brush compartment.
-
Take out the worn brush.
EN
25