Descargar Imprimir esta página

Ivoclar Vivadent Programat EP 5010 G2 Instrucciones Breves página 9

Ocultar thumbs Ver también para Programat EP 5010 G2:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
4. Operation
Start-up
Connect the power cord with the wall
socket and put the On/Off switch at the
rear of the furnace to position "I". After
the self-test is completed, the furnace will
automatically display the screen to select
the desired operating mode. Select the
firing or press mode.
4.1 Operation in the FIRING mode
Step 1:
Select the program type.
The furnace offers several types of
programs:
firing programs for Ivoclar Vivadent
materials
500 free, individually adjustable firing programs
Step 2:
Select the program group.
The program types are subdivided into
program groups. Each program group
consists of 20 programs.
Step 3:
Select the desired firing program.
In this screen, firing programs can be
started or edited.
Step 4:
Edit the firing program.
To edit a parameter, press the respective
button and enter the desired value.
Subsequently, confirm the entry by pressing
Bitte EN
the green button.
When the furnace is delivered ex factory,
Ivoclar Vivadent programs are write-
protected. The write-protection can be
deactivated in the Options menu, where
additional program options are available.
Bitte EN mit Flamme
Step 5:
Load the furnace and start the program.
Open the furnace head using the OPEN FURNACE HEAD key and position
the firing tray with the object in the furnace. Activate the program by
pressing the START key.
Bitte EN mit Flamme
Programat Infrared Technology: Please read the information provided in
Chapter 6.5 of the Operating Instructions thoroughly before the initial
start-up of this furnace. The notes regarding the Programat Infrared
Technology must always be observed!
9

Publicidad

loading