4174
Ausschwingrotor 4-fach /
Swing out rotor 4-times
90°
max. Laufzyklen / max. cycles:
30000 (4500RPM)
60000 (4000 RPM)
80000 (3500 RPM)
Kapazität / capacity
ml
Maße / dimensions  x L
mm
Anzahl p. Rotor / number p. rotor
Drehzahl / speed
RPM
RZB / RCF
2)
Radius / radius
mm
9 (97%)
sec
9
sec
Temperatur / temperature
°C
4174
Ausschwingrotor 4-fach /
Swing out rotor 4-times
90°
max. Laufzyklen / max. cycles:
30000 (4500 RPM)
60000 (4000 RPM)
80000 (3500 RPM)
Kapazität / capacity
ml
Maße / dimensions
mm
TxBxH / DxWxH
Anzahl p. Rotor / number p. rotor
Drehzahl / speed
RPM
2)
RZB / RCF
Radius / radius
mm
sec
9 (97%)
sec
9
Temperatur / temperature
°C
1)
Tiefste erreichbare Temperatur bei maximaler Drehzahl, 1 h Lauf-
zeit und 20°C Raumtemperatur
2)
Angaben des Röhrchenherstellers beachten.
8)
Bei Temperaturen über 40 °C und/oder geringer Befüllung der Gefäße
können sich diese verformen.
12) Ausgleichseinsatz. Handhabung siehe in Kapitel "Beladen des Rotors".
13) Ausgleichsgewichte Set (4566) erhältlich. Handhabung siehe in Kapitel
"Beladen des Rotors".
14) Einsatz mit Schlitzen für Bänder zur Fixierung der Blutbeutel.
MTP Mikrotiterplatte /
Microtitre plate
4547-B
max. Laufzyklen / max. cycles: 30000
max. Beladung / max. load: 1200 g
4443
- - -
- - -
- - -
- - -
- - -
8)
290
- - -
62 x 137
- - -
4
- - -
5411
- - -
239
- - -
1)
4523-A
max. Laufzyklen / max. cycles:
10000 (4500 RPM)
20000 (4000 RPM)
30000 (3500 RPM)
max. Beladung / max. load: 1200 g
4508
14)
4-fach
1-fach
/ 4-
/ 1-
4589-A
times
times
12)
13)
500
750
- - -
- - -
- - -
4
5660
250
1)
3
CP Kulturplatte /
DWP Deep Well Platte /
Culture plate
+
5621
+
---
SK 61.98
4548
---
4-fach
---
- - -
/ 4-
times
---
---
50
500
---
29 x 115
- - -
---
20
4500
---
5094
5524
---
225
244
125
197
-9
- - -
- - -
- - -
- - -
SK 03.18
- - -
- - -
1-fach
- - -
MTP
/ 1-times
- - -
300
- - -
- - -
- - -
- - -
86x128x15 86x128x17,5 86x128x46
4
- - -
24
4500
5456
- - -
241
- - -
125
197
- - -
1)
Lowest possible temperature during maximum speed, 1 h running
time and 20°C ambient temperature
2)
Observe the tube manufacturer's instructions.
8)
At temperatures above 40 °C and/or poor filling of the tubes, these
can go out of shape.
12)
Compensation insert. For handling see chapter "Loading the rotor".
13)
Balance weights set (4566) available. For handling see chapter
"Loading the rotor".
14)
Insert with slots for straps for fixing the blood bags
MS Micronic System /
Deep well plate
4523-A
max. Laufzyklen / max. cycles:
10000 (4500 RPM)
20000 (4000 RPM)
30000 (3500 RPM)
max. Beladung / max. load: 1200 g
4516-A
3-fach
4-fach
1-fach
/ 3-
/ 4-
/ 1-
4589-A
times
times
times
12)
13)
13)
450
500
750
- - -
- - -
- - -
4
4
5660
250
3
SK 06.07 + 5629
+
max. Laufzyklen / max. cycles:
30000 (4500 RPM)
60000 (4000 RPM)
80000 (3500 RPM)
max. Beladung / max. load: 700 g
4626
MTP
MS
- - -
- - -
20
4
4324
191
- - -
QP Filterplatte /
Micronic system
- - -
- - -
1-fach
/ 1-times
13)
1000
- - -
4
5705
252
CP
- - -
86x128x22
16
Filter plate
14 / 33