OPERATING INSTRUCTIONS
POWER INSTRUCTIONS
The treadmill should be grounded. If the unit malfunctions or breaks, grounding
offers a path of less resistance to electric current, which reduces the risk of electrical
shock. The unit is equipped with a suitable power supply socket with an equipment-
grounding wire and a plug with a grounding pin.
Only bipolar plugs with grounding contact will be accepted (2P + T 16A according
to NBR 14136). Any type of adaptation for sockets that do not have a ground pin is
forbidden. The outlets should always be installed in appropriate boxes that do not
allow their poles (of the outlet) to be exposed. All outlets must be connected to the
grounding pin. It is totally unacceptable to use a short circuit (when installation is
possible) short-circuited to the ground.
WARNING!
Inadequate connection of the equipment in the equipment may result in a
risk of electric shock. Consult a quali ed professional or maintenance
personnel if you do not know if the unit is properly grounded.
If you do not t the socket, get a proper socket installed by a quali ed
electrician.
C
AUTION
According to NBR 5410, a thermomagnetic protection circuit breaker with
the following characteristics must be provided at the speci c outlet where
the equipment will be connected:
• Fuse:
• Fuse: 15 Amp-Walls127v.
The circuit breaker has the function of protecting the equipment in the
event of an electrical malfunction that causes the electrical current to
increase in a dangerous manner.
NOTE: THE INSTALLATION OF THE BREAKER SHOULD BE
ACCORDING TO THE NBR 5410 FORM, MANDATORY FOR LOW
VOLTAGE
RESPONSIBILITY OF THE INSTALLER AND THE USER.
!
10
Amps-Walls220v.
INSTALLATIONS,
ITS
INSTALLATION
31
T
F
N
16 A